send a show to the BR-MultiBrick32 while the Write Protect
switch is in the ‘locked’ position.
5) Record: This LED is turned on whenever a revision 1.nn BR-
MultiBrick32 has had its Record Enable’ button pushed. It indi-
cates that the BR-MultiBrick32 has had its DMX-512 and 'Smart'
Brick Network ports disabled and the RS-422 port enabled. This LED
must be ON to talk to the BR-MultiBrick32 through the RS-422 seri-
al port.
In revision 2.00 and later BR-MultiBrick32 hardware there is no
Record Enable’ button. The RS-422 port, BrickNet, and DMX-512
ports are always available. This LED will light whenever the card is
being configured and flash when it is receiving an AutoDownload
file.
6) Output LEDs (Revision 2.00 and Later Cards Only): These thirty-
two LEDs show the current status of the thirty-two digital outputs. If
a LED is lit, then that output is ‘ON’. Because the outputs of a BR-
MultiBrick32 are ‘Open Collector, Switch To Ground’, you can
ground out any output pin, and the appropriate LED will light. This
can be useful when diagnosing output wiring problems. If you are
commanding ‘on’ an output and you don’t see a LED, then the
output is probably drawing too much current and the output is
‘self protecting’. Disconnect the load and see if the LED now
lights. If it does, then it definitely is an overload problem. If it does
not, then try turning ‘on’ some of the other outputs. if they light
OK, then the output driver might be damaged. If they do not,
then verify your addressing and retest.
7) Fuses (Revision 2.00 and Later Cards Only): The thirty-two out-
puts of the BR-MultiBrick32 are divided into four, eight-bit ‘chan-
nels’. Each of these channels is fused for approximately one Amp
of continuous current. These four LEDs light to show if the four
fuses are OK. If any are out, then a short circuit (or too heavy of a
load) is dragging the outputs down and causing the fuse to open.
The fuses are actually ‘PTC fuses’, which act more like circuit
breakers. Once the overload is removed, they reset.